Skip to main content
CarbonMeld CarbonMeld Carbon Observatory

LBC-GFSC — Gestion Forestière à Stock Continu

About this methodology

Owners of French forests that could be harvested manage them to keep a high, continuous stock of standing trees over the project. The method credits the carbon kept in the trees and in wood products, compared with full or partial harvest followed by regrowth.

Status
Active at Label bas-carbone · source ·
Climate outcome
Emission reductions and CO2 removals
Activity
Forestry

How our current method reads projects of this type

Versions of the official text these rules cover: Arrêté du 5 septembre 2025 (référentiel du Label bas carbone), Méthode Plantation de vergers (23 Oct 2020), Méthode Haies v2 (08/06/2021), Méthode boisement v3 (02/09/2025), Méthode boisement v2 (27/07/2020), Méthode reconstitution de peuplements forestiers dégradés v2 (27/07/2020)

What CarbonMeld reads

  • Integrity shown

    Additionality: the project must show it with a test (Arrêté du 5 septembre 2025 art. 2, p. 2). CarbonMeld reads the test in the documents.CM-F-LABEL-BAS-CARBONE-FOREST-ADDITIONALITY

    Link
  • shown

    Leakage: the methodology sets rules for it (Arrêté du 5 septembre 2025 art. 9, p. 6). CarbonMeld reads it in the project's documents. The Boisement, Reconstitution, Plantation de vergers and Haies methods set no leakage term.CM-F-LABEL-BAS-CARBONE-FOREST-LEAKAGE

    Link
  • shown

    Permanence and reversals: the methodology sets rules for it (Boisement v3 §1, p. 7). CarbonMeld reads it in the project's documents.CM-F-LABEL-BAS-CARBONE-FOREST-PERMANENCE-REVERSAL

    Link

Deductions that can apply

  • Integrity deduction −1.5

    Forest, wetland, peat, grassland and soil carbon: if the documents read do not address leakage, CarbonMeld lowers integrity by 1.5 and shows a red flag. Outside REDD+ and reforestation, the gate applies only where the methodology requires a leakage assessment. At the listing stage, the gate does not apply when the programme's listing form has no section on leakage.CM-G-LEAKAGE-NOT-ADDRESSED

    since engine 72 Link

Not applicable to this type — never a gap in our current method

The criterion does not apply to this methodology. Our current method never counts it as a gap.

  • Grid emission factorCM-N-GRID-EF
  • Buffer poolCM-N-BUFFER
  • Fraction of non-renewable biomass (fNRB)CM-N-FNRB
  • Usage rate of the devicesCM-N-USAGE
  • Durability of the storageCM-N-DURABILITY-MEASUREMENT
  • Sustainability of the feedstockCM-N-FEEDSTOCK-SUSTAINABILITY
  • Tracking of the end useCM-N-END-USE-TRACKING
  • Social safeguards and consent of communities (FPIC)CM-N-SAFEGUARDS-FPIC

The general rules apply as well. Read the general rules.

Projects using LBC-GFSC

Browse 35 published projects using LBC-GFSC, listed alphabetically. There is no ranking for this methodology yet: it appears here automatically once 5 of its projects are rated. Open a project to view its registry details and the analysis available for that project.

← All leaderboards · Full database