Grid emission factor: the methodology sets rules for it in some cases. CarbonMeld reads it in the project's documents. CM-F-VM0008-GRID-EF
VM0008 — Weatherization of Single Family and Multi-Family Buildings
About this methodology
Projects improve home insulation, air sealing or energy-using equipment such as heating and cooling systems. The method measures emissions saved by reducing household energy consumption.
- Issued by
- Verra (VCS) · issuer's site
- Version
- 1.2 · source ·
- Status
- Active at Verra / Verified Carbon Standard · source ·
- Climate outcome
- Emission reductions
- Activity
- Buildings
- Official page
- verra.org ·
How methodology v3 reads projects of this type
What CarbonMeld reads
- shown
- shown
Leakage: the methodology sets rules for it in some cases (VM0008 v1.2, p. 11). CarbonMeld reads it in the project's documents. CM-F-VM0008-LEAKAGE
A confirmed investment analysis A-INVEST
The documents show a project-level additionality test, the validation confirmed it, and it is an investment analysis (a numeric test of the project's finances with and without carbon revenue).
Set by the methodology or the programme, not assessed by our current method
- not assessed
Social safeguards and consent of communities (FPIC): any such rules come from the programme, not the methodology. Our current method does not assess it. CM-F-VM0008-SAFEGUARDS-FPIC
Not applicable to this type — never a gap in our current method
The criterion does not apply to this methodology. Our current method never counts it as a gap.
- CM-N-BUFFERBuffer pool
- CM-N-PERMANENCE-REVERSALPermanence and reversals
- CM-N-FNRBFraction of non-renewable biomass (fNRB)
- CM-N-USAGEUsage rate of the devices
- CM-N-REGULATORY-SURPLUSNo legal requirement for the activity
- CM-N-DURABILITY-MEASUREMENTDurability of the storage
- CM-N-FEEDSTOCK-SUSTAINABILITYSustainability of the feedstock
- CM-N-END-USE-TRACKINGTracking of the end use
The general rules apply as well. Read the general rules.
The rules of methodology v2.2, as they were: the archived v2.2 page.
History and transitions
-
v1.2active from 4 Jun 2025currentsource
Adoption of the most recent VCS Methodology Template Inclusion of HP and HPWH as appliances in Category C and fuel switching in Category A/B approach 2, and Category C and D Inclusion of leakage emissions from HCFC leaks from appliances …
-
v1.1active from 10 Oct 2012 – 3 Jun 2025source
Revised to conform with VCS requirements for standardized methods.
-
v1.0active from 7 Dec 2010 – 9 Oct 2012source
Initial version
Projects using VM0008
Browse 11 published projects using VM0008, listed alphabetically. There is no ranking for this methodology yet: it appears here automatically once 5 of its projects not in the pipeline or under validation are rated. Open a project to view its registry details and the analysis available for that project.
Which registries list projects under VM0008?
In CarbonMeld's data, VM0008 projects are on one registry: Verra (11 projects, 2 registered).
| Registry | Projects | Registered | Projects list |
|---|---|---|---|
| Verra (VCS) | 11 | 2 | See the list |
Counts of project records in CarbonMeld's data, with or without a CarbonMeld analysis. «Registered» counts the records whose current registry status is «registered», as last read (15 November 2026); projects in a later status, such as awaiting verification approval, late to verify or completed, are not in that column.
- Analysis: No rating yet
- Analysis: No rating yet
- Analysis: No rating yet
- Analysis: Rating withdrawn — under review
- Analysis: No rating yet
- Analysis: No rating yet
- Analysis: No rating yet
- Analysis: No rating yet
- Analysis: No rating yet
- Analysis: Not registered
- Analysis: No rating yet