Skip to main content
CDMEE supply sideArgentinaACM0007

Conversion of existing open cycle gas turbine to combined cycle at the Central Termica Patagonia power station, Comodoro Rivadavia, Argentina

CDM-1482 ↗

#8of 18 in Argentina#586of 1459 in CDM (UNFCCC)#3of 8 in ACM0007

5.3/ 10
Integrity
5.0
Transparency
5.5
Claim Safety
5.5
Documentation
5.5

Audit Analysis

A CDM combined-cycle conversion project in Argentina with VVB-confirmed additionality and a jurisdictional baseline, but undermined by 13 corrective action requests, a three-way grid emission factor discrepancy (0.419, 0.49, 0.63 tCO₂/MWh), and a baseline-method contradiction between monitoring reports. The project delivered roughly 99% of its pro-rata expectation for the 7-month monitoring period, and all corrective actions were resolved, but the volume of monitoring deficiencies and data inconsistencies limit confidence in the underlying MRV.

Red Flags

  • Three different grid emission factor values appear across documents: 0.419 (2010 monitoring report), 0.49 (project proponent, noted in material findings), and 0.63 (2013 monitoring report) — a 50% spread that materially affects the credit quantity
  • 13 Corrective Action Requests and 4 Clarification Requests were raised during verification, covering missing monitoring parameters (NCVi, EFCO2,i, OXIDi), non-independent meters, unaccounted diesel emissions, and calibration gaps
  • Baseline method is reported as 'jurisdictional' in the 2013 monitoring report but as 'project' in the 2010 monitoring report — an unresolved contradiction that affects the validity of the baseline
  • Crediting period differs between the PDD (2008-06-01 to 2015-05-31) and the 2013 monitoring report (2009-05-31 to 2016-05-30), creating ambiguity about the actual project duration

Credit Vintages

IssuedRetiredAvailable
2012
170,1600170,160
2013
123,6070123,607
Total293,7670293,767

Risk Indicators

Additionality

Combined test, VVB-confirmed

Permanence

EE supply-side, no reversal risk

Leakage

0% deemed negligible, reasonable for EE

Baseline

Jurisdictional per 2013, but contradicted by 2010 report

Safeguards

Safeguards mentioned, benefit sharing described, but FPIC an

Double-claim

CORSIA and CCP status not stated in extracted record

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-08-27ACM0007

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.