Skip to main content
GSEnergy Efficiency - DomesticNepalGeneral Methodologyv2.1

GS11935 GS11934 RVPA-13 Promoting sustainable use of biomass energy resources in targeted communities

GS-4689 ↗ · current registry ID: GS12712

#442of 1329 in Industrial#33of 101 in Nepal#701of 1801 in Gold Standard (GS)

5.1/ 10
Integrity
5.2
Transparency
5.5
Claim Safety
4.5
Documentation
5.5

Audit Analysis

A Gold Standard cookstove project in Nepal with VVB-confirmed additionality and a quantified 5% leakage deduction, but undermined by a 100% usage-rate assumption, a project-specific baseline with no stated reassessment, no buffer pool, and a roughly 9× over-delivery of verified emissions reductions relative to the pro-rata ex-ante expectation. Multiple corrective actions and contradictions across documents further erode confidence in the data quality.

Red Flags

  • Verified ERR of 87,941 is approximately 919% of the pro-rata ex-ante expectation (47,855 lifetime estimate ÷ 5-year crediting period × 1-year monitoring period ≈ 9,571), indicating a very large over-delivery that warrants scrutiny of the ex-ante estimate or the verified figure.
  • Usage rate assumed and verified at 100%, which is an extremely aggressive assumption for household cookstove adoption and use in rural Nepal; the PDD lists a value of 1.0, creating a unit or interpretation ambiguity.
  • No buffer pool is stated in any available document, leaving no financial or credit-based protection against potential reversal (e.g., stove replacement or abandonment).
  • FPIC status is contradictory: the earlier validation report (Nov 2023) records it as conducted, while the later validation report (Sep 2024) records it as not conducted.
  • Seven corrective action requests and six forward action requests were raised during verification, including issues with leakage calculation transparency, non-conservative vintage dating, and SDG reporting errors.

Credit Vintages

IssuedRetiredAvailable
2023
6,81106,811
2024
2,37502,375
Total9,18609,186

Risk Indicators

Additionality

VVB-confirmed combined test

Permanence

cookstove replacement risk

Leakage

5% quantified deduction applied

Baseline

Project-specific; reassessment timing not stated

Safeguards

Grievance mechanism present; FPIC not conducted (per latest validation)

Double-claim

CORSIA and CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-02General Methodology v2.1

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents