Advanced Refrigeration - ARS2020002
#7of 108 in Water#24of 345 in United States#14of 147 in American Carbon Registry (ACR)
Audit Analysis
A California advanced refrigeration project (ACR-791) with a VVB-verified combined additionality test and jurisdictional baseline. The verified emissions reductions (13,360 tCO₂e) match the ex-ante lifetime estimate (13,365 tCO₂e) to within 0.04%, consistent with a one-time refrigerant replacement credit. Four material findings related to data-quality issues (cooling capacity, charge sizes, store dates, parameter references) were identified and corrected, but the thin leakage justification and absence of a documented grievance mechanism limit confidence.
Red Flags
- Four material findings in the verification report (2022) flagged inconsistencies in cooling capacity calculations, refrigerant charge sizes, and store opening dates — all corrected but indicating initial data-quality weaknesses
- Leakage justification is inconsistent across documents: the validation report (2022-09) records it as 'not addressed' while the PDD (2022-11) states it was 'deemed negligible' with no quantified analysis
- No grievance mechanism or FPIC documentation found in the extracted record, despite safeguards being mentioned
Credit Vintages Exhausted
| Issued | Retired | Available | ||
|---|---|---|---|---|
| 2020 | 13,360 | 13,360 | 0 | |
| Total | 13,360 | 13,360 | 0 |
Risk Indicators
VVB-verified combined test
No reversal risk (industrial refrigeration)
0% deduction, 'deemed negligible' only
Jurisdictional baseline
Mentioned but no grievance mechanism or FPIC documented
CORSIA and CCP status not stated
⚑ Dispute this rating
Are you the project owner?
Metadata correction (free)
Name, country, marketplace or links incorrect? Let us know.
Does not modify the score.
[email protected] →Pipeline re-run with new documents
Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.
Submit Documents →