Skip to main content
ACRIndustrial Process EmissionsMISSOURI, USGeneral Methodologyv2.1

Advanced Refrigeration CAN - ARS 002C

ACR-529 ↗

#90of 110 in Water#300of 389 in United States#159of 195 in American Carbon Registry (ACR)

4.0/ 10
Integrity
4.0
Transparency
4.5
Claim Safety
3.5
Documentation
4.0

Audit Analysis

This ACR refrigeration project (replacing high-GWP refrigerants with lower-GWP alternatives) has VVB-confirmed additionality and an inherently sound project design, but the verification report identified 11 material findings including incorrect GWP values, wrong baseline charge sizes, and a missing boundary element (SSR 7). The verified ERR of 1,000,000 tCO2e over a 3-year monitoring period represents 371% of the pro-rata expectation derived from the 1,077,179 tCO2e lifetime ex-ante estimate, raising serious over-crediting concerns. Leakage is deducted at 0% with contradictory justifications across documents.

Red Flags

  • Verified ERR of 1,000,000 tCO2e over 3 years is 371% of the pro-rata expectation (269,295 tCO2e) derived from the 1,077,179 tCO2e lifetime ex-ante estimate over 12 years — a ratio that is very difficult to reconcile
  • The verification report (April 2021) lists 11 material findings including an incorrect GWP applied to R-290, wrong baseline charge sizes, and SSR 7 (Equipment Disposal) excluded from the project boundary — all of which directly affect the accuracy of the claimed ERR
  • Leakage justification is contradictory: the validation report (April 2021) states it was 'not addressed' while the PDD (February 2021) claims it was 'deemed negligible', with a 0% deduction applied
  • The verification report references registry codes ACR479, ACR480, and ACR526 in its findings, which differ from this project's code ACR-529, suggesting possible cross-project data contamination or a multi-project verification scope that is not clearly delineated

Credit Vintages Exhausted

IssuedRetiredAvailable
2017
32,46832,4680
Total32,46832,4680

Risk Indicators

Additionality

VVB-confirmed combined test

Permanence

No reversal risk (refrigerant substitution)

Leakage

0% deduction, contradictory justification

Baseline

Project-specific, calculation errors found

Safeguards

Mentioned but no FPIC or grievance detail

Double-claim

CORSIA and CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-12General Methodology v2.1

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.