Skip to main content
GSSolar Thermal - ElectricityIndiaACM0002

Bundled Solar Project 2 by Aditya Birla Group of Companies

GS-2037 ↗ · current registry ID: GS7549

#479of 1935 in Renewable energy#248of 975 in India#217of 1801 in Gold Standard (GS)#359of 1287 in ACM0002

5.8/ 10
Integrity
6.0
Transparency
6.0
Claim Safety
5.0
Documentation
6.5

Audit Analysis

A Gold Standard solar thermal electricity project in India with a VVB-confirmed investment additionality test and a well-known verification body (Applus+ Certification). However, a project-specific baseline, a 0% leakage deduction with only a 'deemed negligible' justification, and a verified ERR roughly three times the pro-rata ex-ante expectation raise material concerns about baseline robustness and over-crediting risk. Several key fields (buffer pool, CORSIA/CCP status, FNRB) are absent from the extracted record, limiting the depth of assurance.

Red Flags

  • Verified ERR of 106,789 tCO₂e is approximately 295% of the pro-rata ex-ante expectation (~36,200 tCO₂e) for the elapsed monitoring period, indicating a very large over-delivery relative to the PDD estimate of 77,735 tCO₂e for the full 5-year crediting period.
  • The monitoring period (2022-09-01 to 2024-12-31) extends approximately two months beyond the crediting period end date (2024-10-24), meaning part of the verified emissions reductions may fall outside the valid crediting window.
  • Baseline method is contradictory: the verification report (2023-10-23) describes a project-specific baseline while the monitoring report (2023-10-04) describes a jurisdictional baseline; the VVB's project-specific characterisation is less robust.
  • No buffer pool percentage is stated in any available document, leaving permanence risk unquantified despite the absence of a stated reversal-risk mitigation mechanism.
  • FPIC status is directly contradictory: the validation report (2021-11-15) records FPIC as conducted, while the PDD (same date) records it as not conducted.

Credit Vintages

IssuedRetiredAvailable
2019
13,91413,9140
2020
77,19577,1950
2021
77,39142976,962
2022
50,873050,873
Total219,37391,538127,835

Risk Indicators

Additionality

VVB-confirmed investment test

Permanence

low inherent reversal risk for solar

Leakage

0% deduction, 'deemed negligible' but VVB report silent

Baseline

Project-specific per VVB; no reassessment date stated

Safeguards

FPIC and grievance mechanism present but FPIC status contradictory

Double-claim

CORSIA and CCP status both not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-01ACM0002

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents