GS1247 VPA 90 Southern Ethiopia Efficient Cook Stoves
GS-947 ↗ · current registry ID: GS5326
#256of 1329 in Industrial#5of 36 in Ethiopia#431of 1801 in Gold Standard (GS)
Audit Analysis
A Gold Standard cook-stove project in Southern Ethiopia with VVB-confirmed additionality, no reversal events, and a quantified 5% leakage deduction, but undermined by a project-specific baseline, the absence of a buffer pool, 185 non-functional stoves identified during verification, and a large volume of material findings and corrective actions that signal ongoing data-quality issues. The fNRB was revised downward from 0.93 to 0.83 between the 2024 and 2026 verification reports, suggesting the earlier period may have been slightly over-credited.
Red Flags
- 185 non-functional stoves identified during the May 2025 maintenance campaign while the survey reported 100% usage, creating a direct contradiction in the usage-rate evidence
- fNRB value changed from 0.93 (local field, 2024 verification) to 0.83 (national default, 2026 verification), indicating the earlier crediting period may have used an inflated non-renewable burden factor
- No buffer pool is in place despite the energy-efficiency nature of the project where stove breakage and replacement create a tangible reversal risk
- 20 corrective actions and 25+ material findings were raised in the 2026 verification, including transcription errors, formula errors, and inconsistent monitoring-period numbering, pointing to weak internal quality control
- The monitoring report initially combined five VPAs with differing monitoring periods into a single document, a structural transparency deficiency
Credit Vintages
| Issued | Retired | Available | ||
|---|---|---|---|---|
| 2017 | 3,920 | 3,920 | 0 | |
| 2018 | 10,107 | 10,007 | 100 | |
| 2019 | 9,895 | 9,698 | 197 | |
| 2020 | 9,792 | 9,598 | 194 | |
| 2021 | 9,941 | 9,743 | 198 | |
| 2022 | 10,000 | 9,801 | 199 | |
| 2023 | 9,500 | 3,223 | 6,277 | |
| 2024 | 2,485 | 0 | 2,485 | |
| Total | 65,640 | 55,990 | 9,650 |
Risk Indicators
VVB-confirmed combined test
185 non-functional stoves
5% quantified deduction applied
Project-specific; reassessed 2024
FPIC, grievance mechanism, benefit sharing documented
CORSIA and CCP status not stated
⚑ Dispute this rating
Are you the project owner?
Metadata correction (free)
Name, country, marketplace or links incorrect? Let us know.
Does not modify the score.
[email protected] →Pipeline re-run with new documents
Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.
Submit Documents →