Skip to main content
GSEnergy Efficiency - DomesticRwandaGeneral Methodologyv2.1

GS5047 VPA37 African Improved Cookstoves and Clean Water Programme: Nyungwe Rainforest Cookstove Project V

GS-1624 ↗ · current registry ID: GS7452

#710of 1329 in Industrial#52of 139 in Rwanda#1062of 1801 in Gold Standard (GS)

4.8/ 10
Integrity
5.0
Transparency
4.5
Claim Safety
5.0
Documentation
4.5

Audit Analysis

A Gold Standard cookstove project in Rwanda with VVB-confirmed additionality and a combined test, but undermined by a project-specific baseline, no buffer pool or permanence mechanism, a 0% leakage deduction that is internally contradicted, and multiple material findings including non-operational stoves. Eight contradictions across documents and a medium extraction confidence (with file-format metadata polluting the record) reduce confidence in the data integrity.

Red Flags

  • Nine stoves reported non-operational during MP3 and 1.65% of households reported broken stoves, yet no buffer pool or permanence mechanism is documented to cover reversal risk
  • Leakage deduction of 0% justified as 'deemed negligible' in the October 2023 monitoring report, but an earlier May 2023 monitoring report described leakage as 'quantified' — an unresolved methodological contradiction
  • The PDD (2017) states the functional non-replacement baseline (FNRB) was derived from local field data, while the 2023 monitoring report cites a national default — a methodological shift that could inflate claimed reductions
  • FPIC was not conducted (explicitly recorded as false), and the grievance mechanism and safeguards documentation are contradicted between the verification report and the monitoring report within days of each other
  • No lifetime ex-ante ERR figure or verified ERR figure is available in the extracted record, preventing any pro-rata over/under-delivery check

Credit Vintages

IssuedRetiredAvailable
2019
9059050
2020
2,5902,56129
2021
5,7025,589113
2022
5,3835,276107
2023
5,3462,1683,178
2024
4,51804,518
Total24,44416,4997,945

Risk Indicators

Additionality

VVB-confirmed combined test (2023)

Permanence

broken stoves reported

Leakage

0% deduction; justification contradicted

Baseline

Project-specific; no reassessment date

Safeguards

FPIC not conducted; docs inconsistent

Double-claim

CORSIA and CCP status unknown

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-04General Methodology v2.1

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents