GS5658 VPA 13: Water is Life, Madagascar
GS-2111 ↗ · current registry ID: GS7567
#1019of 1329 in Industrial#13of 26 in Madagascar#1455of 1801 in Gold Standard (GS)
Audit Analysis
This Gold Standard PoA VPA in Madagascar displaces decentralized thermal energy (water heating) with a project-specific baseline and a 0% leakage deduction whose justification is contradictory across documents. The verification report covers nine VPAs simultaneously, making the verified ERR figure (64,317) incomparable to the VPA-13 ex-ante lifetime estimate (40,145), and the additionality test type is not stated in the extracted record. Multiple corrective actions and the absence of a physical site visit (remote audit only) further erode confidence in the data quality.
Red Flags
- Verified ERR of 64,317 is ~24× the pro-rata expectation (~1,964) for the 4-month monitoring period against the 40,145 lifetime ex-ante estimate, almost certainly because the verification report aggregates all nine VPAs in the PoA rather than VPA 13 alone — the figures are not on the same basis.
- Additionality test type and VVB confirmation are not stated in any extracted document, leaving the additionality claim unverified in the available record.
- Leakage justification is contradictory: the verification report (2023-12-22) says 'quantified' while the monitoring report (2023-12-20) says 'deemed negligible', yet the deduction is 0% in both cases.
- No physical site visit was conducted due to COVID-19; only remote audit calls were performed, and a Follow-up Action Request (FAR 01) was raised to require a site visit in the next period.
- The verification report is dated 2023-12-22, which falls inside the monitoring period (ending 2023-12-31), raising questions about whether the verification was completed before the period closed.
Credit Vintages
| Issued | Retired | Available | ||
|---|---|---|---|---|
| 2020 | 1,688 | 1,688 | 0 | |
| 2021 | 9,299 | 9,299 | 0 | |
| 2022 | 7,758 | 7,758 | 0 | |
| 2023 | 7,135 | 5,782 | 1,353 | |
| 2024 | 4,932 | 0 | 4,932 | |
| Total | 30,812 | 24,527 | 6,285 |
Risk Indicators
Test type not stated in extracted record
Energy-efficiency project, no reversal risk
0% deduction, contradictory justification
Project-specific, no reassessment date found
Grievance mechanism confirmed post-PDD; FPIC not conducted
CORSIA and CCP status not stated
⚑ Dispute this rating
Are you the project owner?
Metadata correction (free)
Name, country, marketplace or links incorrect? Let us know.
Does not modify the score.
[email protected] →Pipeline re-run with new documents
Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.
Submit Documents →