OYU - Clean Water for Future Leaders
GS-4633 ↗ · current registry ID: GS12980
#155of 1329 in Industrial#4of 19 in Tanzania#282of 1801 in Gold Standard (GS)
Audit Analysis
A Gold Standard safe drinking water supply project in Tanzania with VVB-verified additionality and well-documented safeguards, but significant gaps in verified emissions data, contradictory FNRB and usage-monitoring methods across documents, and a 0% leakage deduction that is difficult to reconcile with the project's reliance on sustained community use. The absence of any verified ERR figure prevents a meaningful over- or under-delivery assessment.
Red Flags
- No verified ERR figure is available in any document, making it impossible to confirm whether claimed reductions are actually being delivered
- FNRB method is stated as 'national default' in the monitoring report but 'local field' in the validation report — a methodological inconsistency that affects the emission factor applied
- Usage monitoring is described as 'assumed' in the monitoring report but 'annual survey' in the PDD, and the assumed usage rate is 100% with no verified measurement
- Leakage deduction is 0% with a 'quantified' justification, yet no quantified leakage figure or methodology is provided in the extracted record
Credit Vintages
No issuances recorded on the registry.
Risk Indicators
VVB-verified combined test
no reversal data
0% deduction, 'quantified' label but no figure
Project-specific; no reassessment date
FPIC, grievance, benefit sharing documented
CCP and CORSIA status not stated
⚑ Dispute this rating
Are you the project owner?
Metadata correction (free)
Name, country, marketplace or links incorrect? Let us know.
Does not modify the score.
[email protected] →Pipeline re-run with new documents
Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.