Skip to main content
GSEnergy Efficiency - IndustrialGermanyAMS-II.I

REMONDIS Recycling CO2 Emissions Reductions from Glass Recycling, Germany

GS-1692 ↗ · current registry ID: GS7435

#1128of 1329 in Industrial#6of 7 in Germany#1578of 1801 in Gold Standard (GS)#51of 72 in AMS-II.I

4.1/ 10
Integrity
4.5
Transparency
4.0
Claim Safety
4.0
Documentation
3.5

Audit Analysis

This Gold Standard glass-recycling energy-efficiency project in Germany has a VVB-confirmed additionality assessment and no reversal risk, but is undermined by an extensive list of material findings and corrective actions (over 25 items), five cross-document contradictions in key emission figures, a project-specific baseline, and a 0% leakage deduction whose justification is inconsistent between the verification and monitoring reports. The low extraction confidence and missing monitoring-method details further erode confidence in the reported figures.

Red Flags

  • Five cross-document contradictions in key figures, including a 5× discrepancy in the lifetime ex-ante emission reduction (1,226 tCO₂e in the 2025 verification report vs 6,130 tCO₂e in the 2025 monitoring report), which makes the true ex-ante baseline uncertain.
  • Over 25 material findings and 21 corrective actions spanning missing calibration certificates, missing invoices, data-entry errors in electricity and diesel consumption, and incomplete PDD sections on baseline and leakage calculation conditions.
  • Leakage treatment is inconsistent: the 2025 verification report states leakage is 'deemed negligible' with a 0% deduction, while the 2023 monitoring report describes it as 'quantified', leaving the actual leakage position ambiguous.
  • The grid emission factor of 0.587 tCO₂/MWh is sourced from 2008 and was flagged for an updated source link, raising the risk that the baseline emission factor is outdated.
  • Low extraction confidence across the document set, meaning at least one key document was poorly readable and the structured data may be incomplete.

Credit Vintages

IssuedRetiredAvailable
2019
2812810
2020
4474470
2021
20850158
2022
2680268
2023
1150115
Total1,319778541

Risk Indicators

Additionality

VVB-confirmed combined test

Permanence

Energy efficiency – no reversal risk

Leakage

0% deduction, inconsistent justification

Baseline

Project-specific, reassessment not stated

Safeguards

Grievance mechanism present, FPIC not stated

Double-claim

CORSIA and CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-06AMS-III.AJ

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents