Skip to main content
VCSEnergy demandGuatemala Registry: Late to verifyAMS-II.G

TUIK RUCH LEW IMPROVED COOKSTOVE PROJECT FOR LAKE ATITLAN

VCS-2077 ↗

#124of 150 in Cookstoves#13of 15 in Guatemala#1080of 1339 in Verra (VCS)#155of 189 in AMS-II.G

4.3/ 10
Integrity
4.5
Transparency
5.0
Claim Safety
3.5
Documentation
4.0

Audit Analysis

The Tuik Ruch Lew cookstove project in Guatemala has VVB-confirmed additionality and a quantified leakage deduction, but is undermined by a severe leakage figure contradiction between the PDD (95%) and the monitoring report (5%), calculation errors flagged by the VVB, absence of FPIC, and a very large gap between the PDD's lifetime estimate and the verified monitoring-period result. The project delivered only about 12% of the pro-rata expectation for the elapsed monitoring period, which is conservative but raises questions about baseline assumptions and data reliability.

Red Flags

  • Leakage deduction contradicts between documents: the PDD states 95% while the monitoring report states 5% — a 19× difference that fundamentally changes the credit volume and cannot be reconciled without further clarification
  • The VVB identified calculation errors and inconsistencies in the SD VISTA MR Calculations Spreadsheet (CAR 01), undermining confidence in the reported 975 tCO2e figure
  • FPIC was not conducted according to the verification report, despite the monitoring report suggesting it was — a direct contradiction on a fundamental safeguard requirement
  • Registry status is 'Late to verify', indicating the project is behind its verification schedule
  • Usage monitoring relies on self-reporting per the verification report, with no independent verification of stove usage rates

Credit Vintages

IssuedRetiredAvailable
2018
331172159
2019
6440644
Total975172803

Risk Indicators

Additionality

VVB-confirmed combined test

Permanence

cookstove reversion risk

Leakage

5% quantified but contradicted by PDD's 95%

Baseline

Project-specific baseline, not jurisdictional

Safeguards

Grievance mechanism present; FPIC not conducted

Double-claim

CORSIA-eligible; CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-08-29CDM AMS-II.G. Small-scale Methodology: Energy efficiency measures in thermal applications of non-renewable biomass

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents