Skip to main content
VCSEnergy industries (renewable/non-renewable sources)India Registry: RegisteredACM0002

Wind Power Project by Green Infra Wind Power Generation Limited

VCS-1776 ↗

#577of 1935 in Renewable energy#278of 975 in India#322of 1339 in Verra (VCS)#445of 1287 in ACM0002

5.7/ 10
Integrity
6.2
Transparency
5.0
Claim Safety
6.3
Documentation
5.0

Audit Analysis

A registered VCS wind power project in India with a solid combined additionality test verified by SGS India and inherent permanence as an avoidance activity. However, multiple corrective action requests across verification cycles reveal recurring inconsistencies in monitoring data (generation apportionment, meter serial numbers, vintage period dates), and the most recent verification report leaves the leakage justification unaddressed. The project appears conservative in its claims (actual reductions exceeded estimates by 6–10%), but documentation quality and data consistency issues temper confidence.

Red Flags

  • Leakage deduction of 0% with justification recorded as 'not addressed' in the most recent verification report (Jan 2025), while an earlier report (Feb 2024) described it as 'quantified' — the justification basis is unclear
  • Multiple CARs across verification cycles flag inconsistencies between the monitoring report and ER calculation sheet (EGPJ,y values, vintage period end dates, check meter serial numbers), indicating recurring MR data-quality problems
  • Baseline method is recorded as 'project' in the verification report but 'jurisdictional' in the monitoring report — the applicable baseline approach is ambiguous
  • Minimum extraction confidence is rated low, meaning at least one key document was poorly readable, reducing reliability of the extracted record

Credit Vintages

IssuedRetiredAvailable
2016
10,6385410,584
2017
79,951079,951
2018
85,651085,651
2019
87,800087,800
2020
75,49535,93939,556
2021
76,85748,68928,168
2022
72,186072,186
2023
80,58024,75255,828
2024
62,6393,72258,917
Total631,797113,156518,641

Risk Indicators

Additionality

Combined test, VVB-verified

Permanence

Avoidance project, no reversal risk

Leakage

0% deduction, justification not addressed

Baseline

Method contradicted across docs; grid EF 2017

Safeguards

FPIC, grievance mechanism, benefit sharing

Double-claim

CORSIA and CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-08-30ACM0002

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents