10MW solar PV based power generation by Helios Beau Champ Limited in Mauritius
#465of 1935 in Renewable energy#300of 1459 in CDM (UNFCCC)#163of 806 in AMS-I.D
Audit Analysis
A 10 MW solar PV project in Mauritius displacing grid electricity, verified under CDM with a jurisdictional baseline and VVB-confirmed additionality. The project delivered roughly 92% of its pro-rata expectation for the first monitoring period, but five corrective action requests—particularly the use of an expired standardized baseline and a DC-vs-AC capacity discrepancy—raise moderate concerns about the robustness of the credit quantity. Documentation is adequate but shows quality-control weaknesses that were flagged and presumably resolved before issuance.
Red Flags
- Corrective Action Request (CAR 04) flagged use of an expired standardized baseline (ASB0019) rather than current grid emission factor data from CEB, undermining baseline currency
- Corrective Action Request (CAR 01) identified discrepancies in project capacity (DC vs AC) and PLF values, which directly affect the credit quantity calculation
- No grievance mechanism or FPIC process is documented in the available record, leaving community-safeguard coverage unverified
Credit Vintages
| Issued | Retired | Available | ||
|---|---|---|---|---|
| 2021 | 17,575 | 0 | 17,575 | |
| Total | 17,575 | 0 | 17,575 |
Risk Indicators
VVB-confirmed test
Avoidance project, no reversal risk
Deemed negligible, appropriate for solar PV
Jurisdictional but expired ASB flagged
Mentioned but no FPIC or grievance mechanism
CORSIA and CCP status not stated
⚑ Dispute this rating
Are you the project owner?
Metadata correction (free)
Name, country, marketplace or links incorrect? Let us know.
Does not modify the score.