22.5 MW grid connected wind farm project by RSMML in Jaisalmer, India.
#1340of 1935 in Renewable energy#716of 975 in India#1062of 1459 in CDM (UNFCCC)#1039of 1287 in ACM0002
Audit Analysis
A 22.5 MW CDM wind project in Jaisalmer, India, with VVB-confirmed additionality and CORSIA eligibility, but undermined by five corrective action requests, a PDD-to-actual-installation mismatch, an unaddressed leakage justification, and a grid emission factor frozen at 2007 values. The project's avoidance-type nature limits reversal risk, yet the volume of material findings and the absence of a verified ERR figure in the extracted record raise meaningful concerns about the robustness of the credit claim.
Red Flags
- PDD specification does not match the windmills actually installed (CL-1 in the 2019 monitoring report), casting doubt on the accuracy of the ex-ante ERR estimate of 282,910 tCO₂e
- Five corrective action requests (CAR-1 through CAR-3) and five compliance-level findings (CL-1 through CL-5) were raised in the 2019 monitoring report, including an inadequately justified additionality analysis (Step 3 alone) and a monitoring method that failed to account for other clients' turbines on the same meter
- Grid emission factor of 0.8971 tCO₂/MWh is anchored to 2007 data; no updated or reassessed value is found in the extracted record for a project operating through 2018
- Leakage justification is recorded as 'not addressed' in the most recent monitoring report (May 2019), contradicting an earlier 2017 report that described it as 'deemed negligible'
- Total verified ERR for the monitoring period (Jan 2017 – Dec 2018) is not found in the extracted record, preventing any pro-rata delivery check against the 282,910 tCO₂e lifetime claim
Credit Vintages
| Issued | Retired | Available | ||
|---|---|---|---|---|
| 2011 | 42,316 | 0 | 42,316 | |
| 2013 | 53,467 | 0 | 53,467 | |
| 2015 | 41,424 | 0 | 41,424 | |
| 2017 | 32,540 | 0 | 32,540 | |
| 2019 | 25,028 | 0 | 25,028 | |
| Total | 194,775 | 0 | 194,775 |
Risk Indicators
VVB-confirmed but Step 3-only gap flagged (CAR-1)
Avoidance-type wind; no reversal risk inherent
0% deduction but justification 'not addressed' in 2019 repor
Project-specific; grid EF frozen at 2007; doc contradiction
FPIC conducted, grievance mechanism present, safeguards docu
CORSIA-eligible; CCP status not stated
⚑ Dispute this rating
Are you the project owner?
Metadata correction (free)
Name, country, marketplace or links incorrect? Let us know.
Does not modify the score.
[email protected] →Pipeline re-run with new documents
Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.
Submit Documents →