Audit Analysis

This CDM waste-heat-recovery project at a Hainan cement plant was validated by TÜV NORD CERT and issued credits, but the extracted record reveals significant gaps: additionality was not confirmed as verified by the VVB, nine material findings were raised during validation (including a non-conservative grid emission factor and an incorrectly structured additionality demonstration), and no monitoring-period or verified-ERR data is available. A seven-fold discrepancy in the claimed ERR between the validation report and an unidentified document further undermines confidence in the credit quantity.

Red Flags

  • Additionality was not confirmed as verified by the VVB, and the validation report flagged that the additionality demonstration was 'incorrectly included for RCP stage'
  • Claimed ERR of 24,895 tCO2e in the validation report is contradicted by a figure of 174,265 tCO2e in an unidentified document — a 7× discrepancy with no reconciliation
  • Nine material findings were raised at validation, including a non-conservative grid emission factor calculation and inconsistent boiler technical data, yet no corrective actions are recorded as required
  • No monitoring period, verified ERR, or FNRB data is available in the extracted record, making post-validation performance unverifiable
  • Minimum extraction confidence is rated low, indicating at least one key document was poorly readable

Credit Vintages

IssuedRetiredAvailable
2010
43,487043,487
2011
66,125066,125
2012
35,837035,837
2013
48,710048,710
Total194,1590194,159

Risk Indicators

Additionality

Test present but not confirmed as VVB-verified; structural e

Permanence

EE project with no reversal risk; no reversal events reporte

Leakage

0% deduction; negligible for grid-displacement WHR project

Baseline

Jurisdictional baseline but PDD/validation report disagree o

Safeguards

Safeguards and benefit-sharing mentioned; no FPIC or grievan

Double-claim

CORSIA and CCP status not stated in available documents

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-08-25ACM0012

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents