The Adiguzel II hydroelectric project has a VVB-confirmed investment additionality test and a jurisdictional grid-emission-factor baseline, but the 2025 verification report shows the project delivered only about 27% of the pro-rata ex-ante expectation for its monitoring period, raising questions about the robustness of the original assumptions. Thirteen corrective actions (all formatting and documentation issues) and a low extraction confidence level temper confidence in the record, while the absence of a buffer pool and the 2012 grid emission factor add residual risk.

Red Flags

  • The 2025 verification report shows 52,448 tCO₂ verified for the 2020–2025 monitoring period, only ~27% of the pro-rata expectation (~192,000 tCO₂) derived from the PDD's 447,405 tCO₂ lifetime estimate over the 10-year crediting period, suggesting the ex-ante baseline may have been overly optimistic or water availability was significantly below assumptions.
  • Thirteen corrective actions were required in the 2025 verification report, all relating to formatting, template compliance, and calculation presentation, indicating weak internal quality control in the project's monitoring documentation.
  • No buffer pool percentage is stated in any available document, leaving no explicit permanence or reversal-risk mitigation mechanism for this avoidance-type project.
  • The grid emission factor of 0.629 tCO₂/MWh is from 2012; if Türkiye's grid has decarbonised since then, the actual per-MWh avoidance is lower than the baseline assumes, compounding the under-delivery concern.

Credit Vintages Exhausted

IssuedRetiredAvailable
2015
31,20831,2080
2016
41,08341,0830
2017
30,29430,2940
2018
21,50621,5060
2019
22,21922,2190
2020
19,70219,7020
Total166,012166,0120

Risk Indicators

Additionality

VVB-confirmed investment test

Permanence

avoidance type

Leakage

Quantified at 0%, reasonable for hydro

Baseline

Jurisdictional but 2012 grid EF; doc contradiction

Safeguards

FPIC and grievance mechanism confirmed (2025 VR)

Double-claim

CORSIA and CCP status not stated

Where to buy

Marketplaces

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-01ACM0002

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.