Biomass based Process Steam Generation Project
#187of 352 in Biomass#797of 975 in India#1194of 1459 in CDM (UNFCCC)#59of 115 in AMS-I.C
Audit Analysis
A CDM biomass steam-generation project in India with a VVB-confirmed investment additionality test, but hampered by five material findings at validation, a ten-fold discrepancy in claimed emissions reductions between the PDD and the validation report, and a near-total absence of monitoring or verification data. The project's inherent permanence risk is low (energy substitution, not carbon storage), yet the data gaps and contradictions significantly undermine confidence in the credit quantity.
Red Flags
- Ten-fold discrepancy in total claimed emissions reductions: the PDD (Apr 2011) states 210,190 tCO₂e while the validation report (May 2011) states 21,019 tCO₂e — a 10× difference that cannot be resolved from available documents
- Five material findings (CAR-1 through CAR-5) at validation, including unsupported elimination of a baseline alternative, missing sensitivity analysis, and an incomplete monitoring plan
- No monitoring-period data, no verified ERR, and no feedstock-sustainability or carbon-content information found in any extracted document
- Minimum extraction confidence rated 'low', indicating at least one key document was poorly readable
Credit Vintages
No issuances recorded on the registry.
Risk Indicators
VVB-confirmed investment test
Energy substitution – no storage risk
0% deduction, minor doc inconsistency
Project-specific, no reassessment data
Mentioned but FPIC/grievance not detailed
CORSIA & CCP status not stated