Braço Norte IV Small Hydro Plant
#1085of 1935 in Renewable energy#90of 211 in Brazil#814of 1459 in CDM (UNFCCC)
Audit Analysis
The Braço Norte IV small hydro project is a CDM-registered renewable energy project with a verified investment-test additionality assessment by TÜV NORD CERT, but it carries a heavy burden of material findings (16 total, including 7 corrective actions) covering calculation errors, unclear emission-factor methodology, and stakeholder-consultation deficiencies. The absence of a buffer pool, inconsistent leakage treatment, and contradictory grid emission-factor values across documents introduce meaningful over-crediting and data-reliability risk. Overall the project is functional but sits in the lower-middle quality band.
Red Flags
- Grid emission factor contradicts itself across monitoring reports: 0.5364 tCO₂/MWh (Jan 2013 report) vs 0.389 tCO₂/MWh (undated report) — a 38 % swing that directly affects credit quantities.
- Seven corrective actions (CARs) were required, including an incorrect crediting-period start date, miscalculated months in first/last year, and inapplicable Step-0 additionality discussion, indicating material errors in the PDD.
- No buffer pool is recorded and leakage is listed as 0 % with the justification marked 'not addressed' in the 2013 monitoring report, despite the validation report claiming it was 'quantified' — an unresolved inconsistency.
- Stakeholder consultation was deficient: local communities, NGOs, and the Public Attorney were not initially invited (CAR 7), and no grievance mechanism or FPIC is documented.
- Multiple non-material findings (NIRs) flag that the emission-factor calculation was unclear in the PDD and that meter calibration procedures were missing from the monitoring plan.
Credit Vintages
| Issued | Retired | Available | ||
|---|---|---|---|---|
| 2008 | 34,905 | 0 | 34,905 | |
| 2009 | 23,130 | 0 | 23,130 | |
| 2010 | 25,974 | 0 | 25,974 | |
| 2012 | 133,823 | 0 | 133,823 | |
| 2013 | 26,660 | 0 | 26,660 | |
| Total | 244,492 | 0 | 244,492 |
Risk Indicators
VVB-confirmed investment test
low inherent risk (hydro)
0% deduction, justification inconsistent across docs
Project-specific; EF contradiction unresolved
No FPIC, no grievance mechanism, CAR 7
Not CORSIA-eligible; CCP not stated
⚑ Dispute this rating
Are you the project owner?
Metadata correction (free)
Name, country, marketplace or links incorrect? Let us know.
Does not modify the score.
[email protected] →Pipeline re-run with new documents
Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.
Submit Documents →