Skip to main content
GSWindChinaACM0002

CNOOC Weifang Binhai Wind Farm Phase II Project

GS-3507 ↗ · current registry ID: GS11560

#1301of 1935 in Renewable energy#784of 1084 in China#1137of 1801 in Gold Standard (GS)#1011of 1287 in ACM0002

4.7/ 10
Integrity
6.0
Transparency
4.0
Claim Safety
4.5
Documentation
3.0

Audit Analysis

A Gold Standard wind farm project with VVB-confirmed additionality and a reasonable leakage treatment, but severely undermined by ten cross-document contradictions, a low extraction confidence rating, and an unresolved discrepancy in the verified emission reduction figures (406,789 vs 102,641 tCO₂e) that raises over-crediting concerns. CORSIA eligibility introduces dual-channel risk, and the project-specific baseline (contradicted by a jurisdictional reference in the monitoring report) weakens baseline robustness.

Red Flags

  • The monitoring report (2022-04-26) contains two conflicting ERR figures — 406,789 and 102,641 tCO₂e — for both claimed and verified values, making it impossible to confirm the correct magnitude of reductions
  • Ten contradictions across documents span baseline method, leakage justification, FPIC status, grievance mechanism, benefit sharing, additionality test type, reversal events, and crediting period, indicating poor internal consistency in the project record
  • CORSIA eligibility is flagged as true for a wind project, creating potential dual-channel crediting risk, while CCP status is not stated in any available document
  • The monitoring period (2024) falls entirely outside the recorded crediting period (2016–2021), and no second crediting period is documented in the extracted record
  • Low extraction confidence across the document set means at least one key document was poorly readable, reducing reliability of all extracted facts

Credit Vintages

IssuedRetiredAvailable
2020
62,03556,1995,836
2021
40,60640,001605
2022
53,81130,00023,811
2023
23,464023,464
Total179,916126,20053,716

Risk Indicators

Additionality

VVB-confirmed investment test

Permanence

Wind project, no reversals reported

Leakage

0% deduction, deemed negligible

Baseline

Project-specific, method contradicted

Safeguards

FPIC and grievance data conflicted

Double-claim

CORSIA-eligible, CCP status unknown

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-01ACM0002

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents