Skip to main content
VCSEnergy industries (renewable/non-renewable sources)Turkey Registry: RegisteredACM0002

Dogançay Weir and Hydroelectric Power Plant

VCS-1003 ↗

#670of 1935 in Renewable energy#138of 295 in Turkey#390of 1339 in Verra (VCS)#517of 1287 in ACM0002

5.5/ 10
Integrity
5.5
Transparency
5.5
Claim Safety
6.0
Documentation
5.0

Audit Analysis

The Doğançay hydroelectric project has a VVB-confirmed investment additionality test and a jurisdictional baseline, but the verification report lists six material findings including calculation errors in baseline and project emissions formulas, and reversal risk is explicitly not addressed. The project delivered roughly 63% of the pro-rata ex-ante expectation for the elapsed monitoring period, indicating conservative (under-)delivery. Multiple contradictions between the 2013 PDD/validation and the 2025 verification report create uncertainty about the project's baseline character and leakage treatment.

Red Flags

  • Six material findings in the 2025 verification report, including calculation errors in baseline and project emissions formulas (CAR 04) and an inconsistency in estimated emission reduction values between the MR and ER sheet (CL 01)
  • Reversal risk is explicitly 'not addressed' and no non-performance risk rating was determined by the project proponent, despite the absence of a buffer pool
  • Corrective actions required list is empty despite the verification report listing multiple CARs, raising questions about whether issues were resolved before issuance
  • Contradiction on baseline method: the 2013 validation report describes a project-specific baseline while the 2025 verification report describes a jurisdictional baseline

Credit Vintages

No issuances recorded on the registry.

Risk Indicators

Additionality

VVB-confirmed investment test

Permanence

Reversal risk not addressed

Leakage

Deemed negligible; reasonable for hydro

Baseline

Jurisdictional per VVB but contradicted by validation report

Safeguards

FPIC conducted; grievance mechanism present

Double-claim

CORSIA and CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-02ACM0002

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents