Audit Analysis

The BioLite Improved Charcoal Stoves project in Kenya is a methodologically sound energy-efficiency intervention with VVB-confirmed additionality and a quantified 5% leakage deduction, but it is undermined by an unusually large volume of material findings and corrective actions spanning MR parameter inconsistencies, missing supporting documents, and database errors. The project-specific baseline and absence of a buffer pool, combined with the lack of a lifetime ex-ante ERR figure for pro-rata comparison, limit confidence in the robustness of the credit claims.

Red Flags

  • Over 50 material findings and 40+ corrective actions identified across verification and validation reports, including hard-coded ER parameters without traceable calculations, missing WBT records, and database linking errors affecting stove counts across multiple VPAs
  • Crediting period discrepancy: the 2022 verification report states 2021–2033 while the 2024 validation report states 2018–2038, creating uncertainty about the applicable crediting window
  • total_err_exante_lifetime is not available in the extracted record, preventing a pro-rata over- or under-delivery assessment against the lifetime estimate

Credit Vintages

IssuedRetiredAvailable
2021
46,10446,1040
2022
36,19435,471723
2023
38,868038,868
Total121,16681,57539,591

Risk Indicators

Additionality

VVB-confirmed combined test

Permanence

no reversals

Leakage

5% quantified deduction

Baseline

Project-specific, measured, reassessed 2024

Safeguards

FPIC, grievance mechanism, safeguards documented

Double-claim

CORSIA and CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-10AMS II. G. “Energy Efficiency Measures in Thermal Applications of Non-Renewable Biomass”

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents