*Honiton Energy Bailingmiao Phase One Windfarm Project

GS-794 ↗ · current registry ID: GS449

#189of 1084 in China#213of 1801 in Gold Standard (GS)#350of 1287 in ACM0002

5.8/ 10
Integrity
5.5
Transparency
6.0
Claim Safety
5.5
Documentation
6.5

Audit Analysis

A Gold Standard wind project in China with a reputable VVB (TÜV NORD CERT) and a jurisdictional baseline, but the record is marred by three material findings (a one-year shutdown, delayed meter calibrations, and spreadsheet data inconsistencies) that required corrective actions. Four cross-document contradictions—particularly the baseline method and grid emission factor—introduce uncertainty into the credit calculation. The project is CCP-approved, and the verified-to-claimed ERR ratio suggests the project is over-delivering relative to its ex-ante estimate, which is a positive signal for claim safety.

Red Flags

  • Three material findings in the 2012 verification report: a full-year shutdown (Apr 2010–Mar 2011), delayed calibration of three meters requiring conservative adjustment, and inconsistencies in emission-reduction spreadsheet traceability
  • Baseline method contradiction: the 2009 verification report describes a project-specific baseline while the 2012 report describes a jurisdictional baseline, creating ambiguity about which method underpins the credits
  • Grid emission factor discrepancy: 1.0548 in the 2012 verification report versus 0.92875 (2014 data) in the 2015 PDD, a ~12% difference that directly affects credit volume
  • Additionality VVB confirmation is not explicitly stated in the extracted record, leaving the investment test's independent verification unconfirmed

Credit Vintages

IssuedRetiredAvailable
2008
99,19699,1960
2009
140,166105,31934,847
2010
19,841019,841
2011
54,296054,296
Total313,499204,515108,984

Risk Indicators

Additionality

Investment test present; VVB confirmation not explicitly stated in record

Permanence

Avoidance project; no inherent reversal risk

Leakage

0% deduction; deemed negligible, reasonable for wind

Baseline

Jurisdictional baseline; contradiction with earlier project-specific description

Safeguards

Grievance mechanism and benefit sharing documented; FPIC not stated

Double-claim

CCP approved; CORSIA eligibility not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-01ACM0002

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents