Skip to main content
VCSEnergy demandMozambique Registry: RegisteredVMR0006

Installation of high efficiency wood burning cookstoves in Mozambique – Project 2

VCS-2888 ↗

#129of 150 in Cookstoves#36of 51 in Mozambique#1103of 1339 in Verra (VCS)#91of 103 in VMR0006

4.2/ 10
Integrity
4.0
Transparency
5.0
Claim Safety
3.5
Documentation
4.5

Audit Analysis

This VCS cookstove project in Mozambique has a confirmed combined additionality test and a quantified 5% leakage deduction, but the verification report raises 12 material findings — most critically that the 91.2% operational cookstove rate is 'likely unrealistic' and the sampling methodology behind it is insufficiently documented. The project delivered only about 4.5% of the pro-rata ex-ante expectation for the elapsed monitoring period, and no buffer pool is stated, leaving permanence and MRV robustness as significant concerns.

Red Flags

  • The verification report explicitly states the 91.2% operational cookstove proportion is 'likely unrealistic' and that the sampling methodology used to determine it is not adequately described or verified
  • 14 corrective actions were required by the VVB, including re-verification of sampling procedures, cross-checking against raw data and project databases, and multiple PDD and validation report updates
  • The project delivered approximately 4.5% of the pro-rata ex-ante expectation for the ~15-month monitoring period (48,799 vs. ~1,076,000 tCO2e expected), raising questions about the realism of the ex-ante estimate or the pace of implementation
  • The validation report (June 2024) records additionality as not verified, contradicting the later verification report (October 2024) which confirms it

Credit Vintages

IssuedRetiredAvailable
2021
1651650
2022
49,27215149,121
Total49,43731649,121

Risk Indicators

Additionality

Combined test confirmed but contradicted by validation report

Permanence

mixed evidence / unresolved risk

Leakage

5% quantified deduction

Baseline

Project-specific baseline, no reassessment date recorded

Safeguards

FPIC conducted, grievance mechanism present

Double-claim

CORSIA and CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-02VMR0006

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.