Skip to main content
GSBiogas - HeatIndiaAMS-I.E

Installation of Household Biogas plants in Punjab - 1

GS-3447 ↗ · current registry ID: GS11426

#65of 268 in Biogas#487of 975 in India#617of 1801 in Gold Standard (GS)#24of 60 in AMS-I.E

5.2/ 10
Integrity
5.0
Transparency
5.5
Claim Safety
5.5
Documentation
4.5

Audit Analysis

A household biogas project in Punjab, India, with a verified additionality test and quantified 5% leakage deduction, but undermined by a serious FPIC contradiction between the PDD and the 2025 verification report, an extensive list of 30+ corrective actions indicating significant MRV data-quality problems, and the absence of a stated buffer pool. Pro-rata delivery of roughly 98% of the expected emissions reductions for the elapsed monitoring period suggests no material over-crediting, yet the data-reliability issues and safeguard gaps limit confidence in the overall claim.

Red Flags

  • FPIC contradiction: the 2022 PDD states FPIC was conducted, but the 2025 verification report records it as not conducted — the more recent verification document is privileged, indicating a fundamental free, prior, and informed consent gap.
  • 30+ corrective actions in the 2025 verification report, including inaccurate ER calculations, incorrect monitoring period, missing sample-size justification, and a technology-description discrepancy (KVIC floating vs. Deenbandhu fixed model), signalling systemic MRV quality problems.
  • FNRB method changed from national default (2022 report) to local field measurement (2025 report) without a clear documented justification for the switch.
  • Baseline is project-specific and no reassessment date is recorded; while not yet overdue under Gold Standard rules, the absence of a documented reassessment schedule is a gap.

Credit Vintages

IssuedRetiredAvailable
2020
2982980
2021
19,46519,4650
2022
32,54032,5400
2023
31,93231,9320
2024
32,02131,412609
2025
18,77618,7760
Total135,032134,423609

Risk Indicators

Additionality

VVB-confirmed combined test

Permanence

mixed evidence / unresolved risk

Leakage

5% quantified deduction

Baseline

Project-specific, no reassessment date recorded

Safeguards

FPIC not conducted per 2025 VR; consultation gaps

Double-claim

CORSIA and CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-05AMS-I.E. Switch from non-renewable biomass for thermal applications by the user

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents