Skip to main content
GSWindTaiwanACM0002

Miaoli 49.8MW Wind Farm Project

GS-1265 ↗ · current registry ID: GS931

#449of 1935 in Renewable energy#2of 6 in Taiwan#198of 1801 in Gold Standard (GS)#337of 1287 in ACM0002

5.9/ 10
Integrity
6.0
Transparency
6.5
Claim Safety
5.5
Documentation
5.5

Audit Analysis

The Miaoli 49.8 MW wind farm is a Gold Standard project with VVB-confirmed additionality and reasonable safeguards, but it is undermined by multiple material findings (meter calibration delays, incorrect meter numbers, obstruction-light failures), a significant under-delivery of roughly 53% of the pro-rata ex-ante expectation for the monitored period, and unresolved contradictions in the baseline method and grid emission factor across verification reports. The project is functional but carries moderate data-reliability and over-crediting risk.

Red Flags

  • Verified emissions reductions (178,044 tCO₂) represent only ~53% of the pro-rata ex-ante expectation (336,834 tCO₂) for the two-year monitoring period, indicating substantial under-delivery or an overly optimistic ex-ante estimate.
  • The 2017 verification report lists at least 14 material findings and corrective actions, including delayed meter calibration, an incorrect meter number used in consumption readings, and non-functioning obstruction lights, raising concerns about the reliability of the monitoring data.
  • The baseline method is described as 'jurisdictional' in the 2017 verification report but as 'project-specific' in the 2015 verification report — an unresolved contradiction that affects the robustness of the counterfactual.
  • The grid emission factor differs between the PDD (0.645 tCO₂/MWh, 2009) and the 2017 verification report (0.714 tCO₂/MWh), and no updated grid factor is documented for the full crediting period.

Credit Vintages

IssuedRetiredAvailable
2010
44,09244,0920
2011
109,155109,1550
2012
97,63295,2002,432
2013
103,58824,60978,979
2014
86,43539,33647,099
2015
88,6571,77386,884
2016
40,63181639,815
Total570,190314,981255,209

Risk Indicators

Additionality

VVB-confirmed combined test

Permanence

Wind avoidance

Leakage

Deemed negligible, reasonable for wind

Baseline

Method contradiction; 2009 grid EF

Safeguards

FPIC, grievance, benefit sharing documented

Double-claim

CORSIA and CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-05ACM0002

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents