Miaoli 49.8MW Wind Farm Project
GS-1265 ↗ · current registry ID: GS931
#449of 1935 in Renewable energy#2of 6 in Taiwan#198of 1801 in Gold Standard (GS)#337of 1287 in ACM0002
Audit Analysis
The Miaoli 49.8 MW wind farm is a Gold Standard project with VVB-confirmed additionality and reasonable safeguards, but it is undermined by multiple material findings (meter calibration delays, incorrect meter numbers, obstruction-light failures), a significant under-delivery of roughly 53% of the pro-rata ex-ante expectation for the monitored period, and unresolved contradictions in the baseline method and grid emission factor across verification reports. The project is functional but carries moderate data-reliability and over-crediting risk.
Red Flags
- Verified emissions reductions (178,044 tCO₂) represent only ~53% of the pro-rata ex-ante expectation (336,834 tCO₂) for the two-year monitoring period, indicating substantial under-delivery or an overly optimistic ex-ante estimate.
- The 2017 verification report lists at least 14 material findings and corrective actions, including delayed meter calibration, an incorrect meter number used in consumption readings, and non-functioning obstruction lights, raising concerns about the reliability of the monitoring data.
- The baseline method is described as 'jurisdictional' in the 2017 verification report but as 'project-specific' in the 2015 verification report — an unresolved contradiction that affects the robustness of the counterfactual.
- The grid emission factor differs between the PDD (0.645 tCO₂/MWh, 2009) and the 2017 verification report (0.714 tCO₂/MWh), and no updated grid factor is documented for the full crediting period.
Credit Vintages
| Issued | Retired | Available | ||
|---|---|---|---|---|
| 2010 | 44,092 | 44,092 | 0 | |
| 2011 | 109,155 | 109,155 | 0 | |
| 2012 | 97,632 | 95,200 | 2,432 | |
| 2013 | 103,588 | 24,609 | 78,979 | |
| 2014 | 86,435 | 39,336 | 47,099 | |
| 2015 | 88,657 | 1,773 | 86,884 | |
| 2016 | 40,631 | 816 | 39,815 | |
| Total | 570,190 | 314,981 | 255,209 |
Risk Indicators
VVB-confirmed combined test
Wind avoidance
Deemed negligible, reasonable for wind
Method contradiction; 2009 grid EF
FPIC, grievance, benefit sharing documented
CORSIA and CCP status not stated
⚑ Dispute this rating
Are you the project owner?
Metadata correction (free)
Name, country, marketplace or links incorrect? Let us know.
Does not modify the score.
[email protected] →Pipeline re-run with new documents
Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.