Skip to main content
VCSEnergy industries (renewable/non-renewable sources); Waste handling and disposalChina Registry: RegisteredAMS-III.G

Wuyang domestic waste treatment plant domestic waste landfill gas (biogas) pollution control and comprehensive utilization project

VCS-2862 ↗

#179of 268 in Biogas#900of 1084 in China#1030of 1339 in Verra (VCS)#25of 34 in AMS-III.G

4.5/ 10
Integrity
4.5
Transparency
4.5
Claim Safety
5.0
Documentation
4.0

Audit Analysis

A registered VCS landfill gas recovery project in China with a VVB-confirmed combined additionality test, but the verification report flagged that regulatory surplus was not demonstrated, undermining the core additionality claim. Nine material findings and nine corrective actions were raised, and the project delivered roughly 85% of its pro-rata ex-ante expectation for the elapsed monitoring period. Documentation quality is further weakened by a low extraction confidence rating and a grid emission factor discrepancy between the monitoring and verification reports.

Red Flags

  • Regulatory surplus not demonstrated: the VVB found the project did not show it goes beyond the legal requirement to capture/destroy landfill gas, a core additionality concern
  • Grid emission factor discrepancy: the monitoring report uses 0.57205 tCO2/MWh (2019) while the verification report references 0.8587, an unexplained ~50% difference
  • Nine material findings and nine corrective actions required, including an incomplete monitoring plan and missing Scope 3 emissions description
  • Leakage justification is inconsistent: the verification report says 'quantified' while the monitoring report says 'deemed negligible', both with a 0% deduction

Credit Vintages

IssuedRetiredAvailable
2021
4,17304,173
2022
36,965036,965
2023
39,240039,240
2024
13,177013,177
Total93,555093,555

Risk Indicators

Additionality

VVB-confirmed but regulatory surplus not demonstrated

Permanence

reversal N/A for LFG

Leakage

0% deduction, justification inconsistent across docs

Baseline

Project-specific, modeled; reassessment not yet due

Safeguards

FPIC conducted, grievance mechanism present

Double-claim

CORSIA and CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-04AMS-III.G, Landfill methane recovery; AMS-I.D, Grid connected renewable electricity generation

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents