Skip to main content
VCSEnergy industries (renewable/non-renewable sources)Turkey Registry: RegisteredAMS-I.D

Yaprak-I Hydropower Plant, Turkey

VCS-1009 ↗

#1196of 1935 in Renewable energy#226of 295 in Turkey#822of 1339 in Verra (VCS)#384of 806 in AMS-I.D

4.9/ 10
Integrity
5.0
Transparency
5.0
Claim Safety
5.0
Documentation
4.5

Audit Analysis

The Yaprak-I Hydropower Plant is a VCS-registered small hydropower project with a jurisdictional baseline and VVB-verified additionality, but its integrity is significantly undermined by extensive material findings including a miscalculation in the ER spreadsheet, shared metering with the adjacent Yaprak-II plant, and numerous inconsistencies between the monitoring report and the project design document. The project delivered approximately 85% of the pro-rata expected emissions reductions for the four-year monitoring period, which is within a reasonable range, but the Gold Standard registration history and unresolved double-claiming questions introduce additional risk.

Red Flags

  • Electricity generation is calculated using a proportional constant due to a shared meter with Yaprak-II HEPP, creating a fundamental MRV weakness and potential for double counting between the two plants
  • A miscalculation in the ER calculation spreadsheet resulted in underestimated electricity generation and emission reductions, indicating a quality-control failure in the project's own calculations
  • The project was initially registered under Gold Standard and subsequently delisted to avoid double counting, raising residual double-claiming risk
  • The 2024 verification report required the project to withdraw its approved verification request and resubmit with a revised monitoring report, verification report, and ERR, indicating the initial verification was not fully reliable
  • FPIC was not conducted despite the project's presence in a community setting in Turkey

Credit Vintages

No issuances recorded on the registry.

Risk Indicators

Additionality

VVB-confirmed regulatory surplus test

Permanence

mixed evidence / unresolved risk

Leakage

0% deemed negligible, appropriate for hydropower

Baseline

Jurisdictional baseline, reassessed 2023

Safeguards

Grievance mechanism present but FPIC not conducted

Double-claim

Prior Gold Standard registration; CORSIA and CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-04AMS-I.D

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents