Skip to main content
VCSEnergy industries (renewable/non-renewable sources)Turkey Registry: RegisteredACM0002

Yumrutepe Regulator and 15.013 MW Hydroelectric Power Plant Project

VCS-1741 ↗

#324of 1935 in Renewable energy#72of 295 in Turkey#166of 1339 in Verra (VCS)#245of 1287 in ACM0002

6.1/ 10
Integrity
6.2
Transparency
5.8
Claim Safety
6.2
Documentation
6.2

Audit Analysis

A 15 MW hydroelectric project in Turkey with a solid combined additionality test confirmed by a reputable VVB (Applus+), but notable gaps in permanence assessment, baseline method consistency, and several monitoring parameters. The project delivered roughly 57–63% of its pro-rata ex-ante expectation for the elapsed monitoring period, indicating conservative crediting. Moderate data-quality issues (10 CARs, 18 CRs) and unresolved contradictions between documents temper confidence.

Red Flags

  • Baseline method is described as 'jurisdictional' in the 2021 verification report but 'project' in the 2019 validation report — an unresolved contradiction that affects baseline credibility
  • Non-permanence risk is explicitly 'not addressed' in the verification report and no buffer pool percentage is stated, despite the absence of a formal reversal-risk rating
  • ERR figures differ across documents (28,883 vs 54,973) and the ex-ante lifetime estimate differs between the PDD (262,241) and the 2019 verification report (238,154), creating ambiguity about the true baseline expectation
  • Ten corrective action requests and eighteen clarification requests were raised during verification, including missing calibration certificates, missing power purchase agreement, and an inconsistency in July 2019 grid-supply figures
  • FNRB methodology, usage monitoring method, and usage rate (assumed and verified) are all absent from the extracted record

Credit Vintages

IssuedRetiredAvailable
2016
306170136
2017
17,0204,00013,020
2018
20,738020,738
2019
20,4836,82913,654
2020
17,14414,1662,978
2021
8,1656,3241,841
Total83,85631,48952,367

Risk Indicators

Additionality

Combined test, VVB-confirmed

Permanence

Not formally assessed

Leakage

0% deemed negligible; reasonable for hydro

Baseline

Jurisdictional per VR but contradicted by validation report

Safeguards

FPIC conducted, grievance mechanism present

Double-claim

CORSIA and CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-04ACM0002

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents