Audit Analysis

A standard CDM waste-heat-recovery project in China with a well-verified investment-test additionality assessment by DNV, but weakened by a 0% leakage deduction whose justification is inconsistent across monitoring reports, a grid emission factor frozen at 2006 values, and several unresolved documentation gaps (no verified ERR figure, no usage-monitoring method stated). The project is mid-crediting-period with no reversal risk, and all material findings from validation have been resolved.

Red Flags

  • Leakage deduction is 0% and the justification is contradictory: the January 2012 monitoring report describes it as 'quantified' while the September 2012 monitoring report states it was 'not addressed' — the later document is privileged, leaving the 0% figure without a clear, documented rationale.
  • Grid emission factor of 0.9746 tCO₂/MWh is drawn from 2006 NDRC data (published August 2007) and has not been updated in the available documents, creating a risk that the baseline overstates or understates actual grid emissions over the full 2008–2018 crediting period.
  • Installed capacity of major equipment (boilers, steam turbine, generator) differed from the PDD description, and nominal generation capacity changed from 20 MW to 26.55 MW during validation; although resolved, this indicates the initial project design documentation was imprecise.

Credit Vintages

IssuedRetiredAvailable
2011
130,0850130,085
2012
49,745049,745
2013
16,805016,805
Total196,6350196,635

Risk Indicators

Additionality

VVB-confirmed investment test, IRR 15.89%

Permanence

EE generation project, no reversal risk

Leakage

0% deduction, justification inconsistent across reports

Baseline

Project-specific, grid EF frozen at 2006 values

Safeguards

Safeguards and benefit sharing mentioned; no FPIC or grievan

Double-claim

CORSIA and CCP status not stated in available documents

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-08-25ACM0004 ver.2

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents