Skip to main content
GSEnergy Efficiency - IndustrialChinaACM0012

Antai Group Waste Gas Recovery for Power Generation Project (300303)

GS-1058 ↗ · current registry ID: GS605

#127of 202 in Industrial#143of 204 in China#302of 426 in Gold Standard (GS)#6of 15 in ACM0012

4.8/ 10
Integrity
4.5
Transparency
4.5
Claim Safety
5.0
Documentation
5.5

Audit Analysis

A Gold Standard waste-gas-to-power project in China with VVB-confirmed additionality and full delivery of claimed credits over its 10-year crediting period. However, the project carries significant quality concerns: over 30 material findings and 28 corrective actions were raised across verification cycles, the grid emission factor dates to 2006, leakage is dismissed as negligible with no quantification, and no buffer pool is in place. The overall picture is of a project that functionally delivered its claims but with weak methodological safeguards and documentation quality.

Red Flags

  • Grid emission factor of 0.9928 tCO2/MWh is from 2006; China's grid mix has shifted since then, potentially inflating the baseline
  • Leakage deduction of 0% justified only as 'deemed negligible' with no quantified analysis, despite the project involving combustible waste gas that could theoretically be diverted
  • Steam monitoring meters required by the PDD were never installed; the project chose not to claim ERs for cogeneration, indicating the monitoring plan was not fully implemented
  • No buffer pool or permanence mechanism is documented for the project
  • 30+ material findings and 28 corrective actions across verification cycles indicate systemic quality-control weaknesses in the project's monitoring and reporting

Credit Vintages

IssuedRetiredAvailable
2008
77,83177,8310
2009
274,309274,3090
2010
271,903271,9030
2011
246,093245,691402
2012
256,741236,42720,314
2013
39,04839,0480
2016
3,7562,757999
2017
250,307250,3070
2018
148,137145,5472,590
Total1,568,1251,543,82024,305

Risk Indicators

Additionality

VVB-confirmed investment test

Permanence

No buffer pool; low inherent risk (energy efficiency)

Leakage

0% deduction, 'deemed negligible' only

Baseline

Project-specific; 2006 grid EF; reassessment not stated

Safeguards

Safeguards and benefit sharing mentioned; FPIC and grievance

Double-claim

CORSIA and CCP status not stated in available documents

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-08-24ACM0012

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents