Skip to main content
CDMMethane avoidanceVietnamAMS-III.H

AVN08-S-02, Methane Recovery and Biogas Utilization Project, Nghe An Province, Vietnam

CDM-2637 ↗

#14of 111 in Biogas#7of 25 in Vietnam#39of 213 in CDM (UNFCCC)#2of 22 in AMS-III.H

5.7/ 10
Integrity
6.5
Transparency
5.0
Claim Safety
5.5
Documentation
5.0

Audit Analysis

A CDM biogas/methane recovery project in Vietnam with a well-supported additionality case (combined test, VVB-verified, capture not legally required) but a project-specific modeled baseline and no buffer pool. The apparent ERR discrepancy between the PDD and validation report is explained by an annual-versus-cumulative reporting basis (47,178 × 7 = 330,246), which is reassuring. Several key MRV parameters (FNRB, usage monitoring, permanence) are absent from the extracted record, limiting confidence in the full claim.

Red Flags

  • Project-specific modeled baseline (not jurisdictional) with last reassessment in 2018; no buffer pool or permanence mechanism documented for a methane-avoidance project
  • FNRB value, usage monitoring method, and usage rate are all absent from the extracted record, leaving the energy-displacement claim partially unverifiable
  • Leakage justification recorded as 'deemed negligible' in the validation report but a second source references a 'quantified' treatment, creating ambiguity about whether leakage was actually calculated

Credit Vintages

IssuedRetiredAvailable
2014
14,101014,101
2015
25,598025,598
2017
41,311041,311
2018
17,468017,468
Total98,478098,478

Risk Indicators

Additionality

Combined test, VVB-verified, capture not legally required

Permanence

No buffer pool or permanence mechanism documented

Leakage

0% deduction, 'deemed negligible' but not quantified

Baseline

Project-specific modeled baseline, last reassessed 2018

Safeguards

Safeguards mentioned, benefit-sharing described, but FPIC an

Double-claim

CORSIA and CCP status not stated in available documents

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-08-25AMS-III.H.: Methane recovery in wastewater treatment; AMS-I.C.: Thermal energy production with or without electricity

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents