Skip to main content
GSEnergy Efficiency - DomesticUgandaAMS-II.G

BioLite Improved Cook stoves Programme - CPA 017 supported by Republic of Korea

GS-3219 ↗ · current registry ID: GS11230

#99of 202 in Industrial#13of 23 in Uganda#252of 426 in Gold Standard (GS)#26of 46 in AMS-II.G

5.0/ 10
Integrity
5.0
Transparency
5.0
Claim Safety
5.5
Documentation
4.5

Audit Analysis

The BioLite Improved Cook Stoves Programme in Uganda has a fundamentally sound design with VVB-confirmed additionality, a quantified 5% leakage deduction, and no reported reversal events. However, the project is undermined by an extensive list of material findings and corrective actions (over 30 items), numerous contradictions between the PDD, validation report, and verification report on key parameters (baseline method, crediting period, FNRB value, and ERR figures), and significant gaps in documentary evidence. The overall picture is of a project with a credible technical foundation but weak data governance and reporting discipline.

Red Flags

  • Over 30 material findings and 20 corrective actions identified across verification and validation cycles, including missing end-user databases, sales records, photos, and training records
  • Crediting period contradicts between the validation report (2018–2038, 20 years) and the verification report (2019–2024, 5 years), creating ambiguity in pro-rata ERR expectations
  • FNRB value differs by an order of magnitude between the PDD (78.75) and the verification report (0.807), suggesting a possible unit or parameter error
  • Baseline method is stated as 'project-specific' in the verification report but 'jurisdictional' in the PDD, with no clear reconciliation
  • Monitoring report (180,153 tCO2e, dated 2026-02-03) reports a higher ERR than the verification report (156,789 tCO2e, dated 2025-12-15), and the monitoring report is dated after the verification report — an unusual sequencing that raises questions about the verification chain

Credit Vintages

IssuedRetiredAvailable
2021
23,18623,1860
2022
24,89324,396497
2023
24,058024,058
2024
20,931020,931
Total93,06847,58245,486

Risk Indicators

Additionality

VVB-confirmed combined test

Permanence

No reversals but buffer pool not stated

Leakage

5% quantified deduction

Baseline

Project-specific, reassessed 2024, method contradicts PDD

Safeguards

FPIC, grievance mechanism, and safeguards documented

Double-claim

CORSIA and CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-08-24AMS II G: Energy efficiency measures in thermal applications of non-renewable biomass

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents