Vai al contenuto principale
GS Biomass, or Liquid Biofuel - Cogeneration Thailand Documentazione completa General Methodology v2.0

Blue Fire Bio wastewater treatment and biogas utilization project (300147)_pre-CDM VER

GS-1191 ↗

4.3 / 10
Integrity
4.8
Transparency
4.1
Claim Safety
4.3
Documentation
3.6

Score Breakdown

Integrity

verified Additionality was confirmed by the VVB using an investment test, which supports the project’s core crediting rationale.

missing Leakage is weakly supported: the monitoring report states leakage was not addressed, and reversal risk is not discussed.

Transparency

verified A named VVB, Germanischer Lloyd Certification GmbH, and a verified emission reduction total of 19,332 are reported in the monitoring report.

missing Key MRV fields are missing or not stated, including usage monitoring details, FNRB treatment, and claimed versus verified ER comparison.

Claim Safety

verified The project uses AMS III.H and a project baseline, which is at least a defined methodological framework.

missing Leakage deduction is shown as 0% despite the report saying leakage was not addressed, creating over-crediting risk.

Documentation

verified Four documents were used and the extraction confidence is medium, so the record is not completely sparse.

missing The monitoring report lists 12 CARs and 5 CLs, and several important fields are not found in the extracted record.

Detailed Analysis

Integrity

The monitoring report confirms additionality through an investment test and shows a verified emission reduction total of 19,332, which is a positive sign. However, leakage is not convincingly handled: the report says leakage was not addressed, yet a 0% leakage deduction is recorded, and reversal events are also not addressed. The presence of 12 CARs and 5 CLs further weakens confidence in the robustness of the project’s crediting integrity.

Transparency

Transparency is mixed because the monitoring report identifies the VVB as Germanischer Lloyd Certification GmbH and provides a monitoring period from 2010-04-09 to 2011-04-08. At the same time, several important MRV elements are not stated in available documents, including usage monitoring method, FNRB treatment, and claimed versus verified ER reconciliation. The record is therefore usable but incomplete.

Claim Safety

Claim safety is constrained by the weak leakage treatment and the contradiction in the record. The project follows AMS III.H and uses a project baseline, but the leakage deduction of 0% is hard to reconcile with the statement that leakage was not addressed. With no clear CORSIA or CCP status available, the project cannot benefit from stronger claim-safety signals.

Documentation

Documentation quality is below average because several key fields are missing from the extracted record, including grievance mechanism, FPIC, buffer pool, and usage monitoring details. The monitoring report is dated 2012-08-27, which is reasonably close to the monitoring period, but the 12 CARs and 5 CLs indicate substantial follow-up was needed. Medium extraction confidence helps, but the overall file set still looks incomplete.

Overall

The main contradiction is on leakage: the older document is said to have quantified leakage, while the 2012-08-27 monitoring report says leakage was not addressed. I privileged the monitoring report because it is the more recent and directly relevant verification-era source, but the inconsistency still lowers reliability. Because the project has VVB-confirmed additionality yet weak leakage handling and many corrective actions, the overall score remains moderate rather than strong.

Audit Analysis

The project has some strengths, including VVB-confirmed additionality and a verified emission reduction figure, but the evidence base is thin and several key safeguards and MRV details are missing. Leakage treatment is unclear, there are many corrective actions, and the record contains a contradiction on leakage justification that reduces confidence in the claims.

Project Description

Developer: South Pole Ltd Type: Biomass, or Liquid Biofuel - Cogeneration Size: Small Scale Methodology: AMS-I.C. Thermal energy production with or without electricity Crediting period: 2007-07-01 → 2017-04-08 Estimated annual credits: 51817 tCO2e SDGs: Goal 3: Good Health and Well-Being, Goal 13: Climate Action, Goal 12: Responsible Production and Consumption

Red Flags

  • Leakage treatment is inconsistent: one document indicates a quantified approach, while the monitoring report says leakage was not addressed.
  • The verification found 12 CARs and 5 CLs, suggesting material documentation and implementation issues.

Credit Vintages

Issued Retired Available
2010
10,613 9,918 695
2011
8,719 8,711 8
Total 19,332 18,629 703

Cosa migliorerebbe questo punteggio

  • Provide a clear, documented leakage assessment and reconcile the 0% deduction with the statement that leakage was not addressed.
  • Publish the missing MRV and safeguards details, including usage monitoring, grievance mechanism, FPIC, and any follow-up closure of the 12 CARs and 5 CLs.

Questi suggerimenti indicano quali prove pubbliche aggiuntive potrebbero migliorare il livello di confidenza di questa valutazione. Non garantiscono un punteggio futuro più alto.

Risk Indicators

Additionality

VVB-confirmed investment test

Permanence

reversal risk not addressed

Leakage

leakage treatment unclear

Baseline

project baseline, reassessment not stated

Safeguards

safeguards mentioned but not documented

Double-claim

CORSIA/CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis Provenance Scored 2026-04-19 General Methodology v2.0 Documentazione completa

Sei il proprietario di questo progetto?

Correzione metadati (gratuita)

Nome, paese, marketplace o link errati? Segnalacelo.

Non modifica lo score.

[email protected]

Rivalutazione con nuovi documenti

Hai documentazione aggiornata non ancora inclusa? Puoi richiedere un nuovo run della pipeline con i nuovi input.

Invia Documenti