Skip to main content
VCSEnergy industries (renewable/non-renewable sources)China Registry: RegisteredACM0002

Grouped Connect Solar PV Power Generation Project in China

VCS-1461 ↗

#55of 770 in Renewable energy#24of 204 in China#70of 629 in Verra (VCS)#38of 383 in ACM0002

6.5/ 10
Integrity
6.5
Transparency
6.5
Claim Safety
7.0
Documentation
5.5

Audit Analysis

A registered VCS solar PV project in China with a solid investment-test additionality assessment confirmed by the VVB and a grid-emission-factor baseline appropriate for the project type. However, four corrective actions, a material finding on pipeline listing, a 0% leakage deduction with no explicit justification, and several cross-document contradictions (additionality test type, baseline method, leakage rationale) introduce moderate uncertainty. The verified ERR for the 2019–2022 monitoring period (946,107 tCO₂e) aligns closely with the pro-rata share of the PDD lifetime estimate, indicating no material over-crediting.

Red Flags

  • Four corrective actions (CAR 01–04) plus two additional VVB requirements were raised in the 2022 verification report, indicating recurring process or quantification deficiencies.
  • Leakage deduction is 0% and the verification report records the justification as 'not addressed'; the monitoring report calls it 'deemed negligible' but no quantitative or qualitative rationale is provided in either document.
  • The PDD describes the additionality test as 'combined' while the validation report (the VVB's own assessment) records it as 'investment' — an inconsistency that weakens the additionality narrative.
  • Baseline method is described as 'project' in the verification report but 'jurisdictional' in the monitoring report, creating ambiguity about which baseline approach was actually applied.

Credit Vintages

IssuedRetiredAvailable
2013
89,76735,35454,413
2014
250,129285249,844
2015
340,589116,989223,600
2016
210,25212,506197,746
2017
224,230221,8132,417
2018
265,092441264,651
Total1,380,059387,388992,671

Risk Indicators

Additionality

VVB-confirmed investment test

Permanence

Solar PV – no carbon stock, minimal reversal risk

Leakage

0% deduction, justification not addressed in verification re

Baseline

Grid-EF baseline appropriate but method description contradi

Safeguards

FPIC, grievance mechanism, benefit sharing all documented

Double-claim

CORSIA and CCP status not stated – dual-channel risk not exc

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-08-25ACM0002

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents