Skip to main content
VCSavoidanceIndiaVintage 2016, 2017 Registry: Verification approval requestedACM0002

Solar Grouped Project By Acme Group (Ekiesl-VCS-Aug-16-01)

VCS-1580 ↗

#887of 1935 in Renewable energy#441of 975 in India#555of 1339 in Verra (VCS)#700of 1287 in ACM0002

5.3/ 10
Integrity
5.5
Transparency
5.0
Claim Safety
6.0
Documentation
4.0

Audit Analysis

A long-running Indian solar avoidance project (ACM0002 v17) with a jurisdictional grid baseline and VVB-confirmed additionality, but plagued by extensive documentation gaps, a methodological flaw in the common-practice analysis, and a low extraction confidence rating. The verified emissions reductions are broadly consistent with the ex-ante estimate on a pro-rata basis, but the volume of corrective actions and material findings across multiple monitoring periods raises concerns about the robustness of the MRV record.

Red Flags

  • Common-practice additionality analysis was initially conducted on combined capacity rather than individually for each large-scale component, contrary to CDM/VCS guidance for grouped projects (noted in the 2026 verification report material findings).
  • The 2026 verification report does not explicitly address reversal/permanence risk, and no buffer pool percentage is stated in any available document.
  • Minimum extraction confidence is rated low, indicating at least one key document was poorly readable, undermining confidence in the extracted data.
  • Seven or more Corrective Action Requests were raised in the latest verification cycle, covering missing JMRs, calibration certificates, stakeholder consultation records, and double-counting undertakings.
  • Benefit-sharing documentation was present in the 2023 verification report but is no longer described in the 2026 verification report, indicating a regression in social-safeguard reporting.

Credit Vintages

IssuedRetiredAvailable
2015
20,38820,3880
2016
401,854401,8540
2017
724,492718,8265,666
2018
666,086666,0860
2019
639,708638,803905
2020
660,368660,3680
2021
458,723458,623100
2023
6,3006,3000
Total3,577,9193,571,2486,671

Risk Indicators

Additionality

VVB-confirmed but common-practice analysis initially done on combined capacity

Permanence

Avoidance project, low inherent risk, but not explicitly addressed in 2026 VR

Leakage

0 % deduction, deemed negligible – appropriate for grid-connected solar

Baseline

Jurisdictional grid EF (0.9777, 2016); 10-year reassessment not yet due

Safeguards

FPIC and grievance mechanism documented, but benefit-sharing reporting regressed by 2026

Double-claim

CORSIA and CCP status not stated in available documents

Where to buy

Marketplaces

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-09-03ACM0002

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents