Solar Grouped Project By Acme Group (Ekiesl-VCS-Aug-16-01)
#887of 1935 in Renewable energy#441of 975 in India#555of 1339 in Verra (VCS)#700of 1287 in ACM0002
Audit Analysis
A long-running Indian solar avoidance project (ACM0002 v17) with a jurisdictional grid baseline and VVB-confirmed additionality, but plagued by extensive documentation gaps, a methodological flaw in the common-practice analysis, and a low extraction confidence rating. The verified emissions reductions are broadly consistent with the ex-ante estimate on a pro-rata basis, but the volume of corrective actions and material findings across multiple monitoring periods raises concerns about the robustness of the MRV record.
Red Flags
- Common-practice additionality analysis was initially conducted on combined capacity rather than individually for each large-scale component, contrary to CDM/VCS guidance for grouped projects (noted in the 2026 verification report material findings).
- The 2026 verification report does not explicitly address reversal/permanence risk, and no buffer pool percentage is stated in any available document.
- Minimum extraction confidence is rated low, indicating at least one key document was poorly readable, undermining confidence in the extracted data.
- Seven or more Corrective Action Requests were raised in the latest verification cycle, covering missing JMRs, calibration certificates, stakeholder consultation records, and double-counting undertakings.
- Benefit-sharing documentation was present in the 2023 verification report but is no longer described in the 2026 verification report, indicating a regression in social-safeguard reporting.
Credit Vintages
| Issued | Retired | Available | ||
|---|---|---|---|---|
| 2015 | 20,388 | 20,388 | 0 | |
| 2016 | 401,854 | 401,854 | 0 | |
| 2017 | 724,492 | 718,826 | 5,666 | |
| 2018 | 666,086 | 666,086 | 0 | |
| 2019 | 639,708 | 638,803 | 905 | |
| 2020 | 660,368 | 660,368 | 0 | |
| 2021 | 458,723 | 458,623 | 100 | |
| 2023 | 6,300 | 6,300 | 0 | |
| Total | 3,577,919 | 3,571,248 | 6,671 |
Risk Indicators
VVB-confirmed but common-practice analysis initially done on combined capacity
Avoidance project, low inherent risk, but not explicitly addressed in 2026 VR
0 % deduction, deemed negligible – appropriate for grid-connected solar
Jurisdictional grid EF (0.9777, 2016); 10-year reassessment not yet due
FPIC and grievance mechanism documented, but benefit-sharing reporting regressed by 2026
CORSIA and CCP status not stated in available documents
Where to buy
Marketplaces
+ Know where to buy this?
Listing multiple projects? Send us a CSV at [email protected].
⚑ Dispute this rating
Are you the project owner?
Metadata correction (free)
Name, country, marketplace or links incorrect? Let us know.
Does not modify the score.
[email protected] →Pipeline re-run with new documents
Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.
Submit Documents →