Skip to main content
VCSEnergy industries (renewable/non-renewable sources)China Registry: RegisteredACM0018

Guangxi Fusui Qiquan biomass power generation project

VCS-1875 ↗

#46of 196 in Biomass#103of 204 in China#349of 629 in Verra (VCS)#3of 6 in ACM0018

5.3/ 10
Integrity
5.2
Transparency
5.8
Claim Safety
5.0
Documentation
5.2

Audit Analysis

A VCS biomass power generation project in China with VVB-confirmed additionality and a named certification body, but undermined by three material findings (including a 64% shortfall in verified reductions versus the project design estimate), nine corrective actions, a contradictory baseline method description, and a weakly justified zero leakage deduction. The project delivered roughly 72% of its pro-rata expectation for the elapsed monitoring period, and several operational details (carbon content testing, feedstock sustainability, LCA) are absent from the record.

Red Flags

  • Three material findings in the 2021 verification report: diesel fuel monitored via purchase invoices rather than a flow meter, verified reductions 64% below the project design estimate, and operating hours 36% below ex-ante assumptions
  • Nine corrective actions (CAR 01–CAR 09) were required, indicating systemic compliance gaps in monitoring and reporting
  • Leakage deduction of 0% is justified as 'deemed negligible' in the verification report, yet the validation report records leakage as 'not addressed' — an unresolved inconsistency
  • Baseline method is described as 'project-specific' in the 2021 monitoring report but 'jurisdictional' in the 2019 monitoring report, creating ambiguity about the reference case
  • Grid emission factor is from 2017, which is the most recent year available in the record but may not reflect current grid conditions for a project operating through 2048

Credit Vintages

IssuedRetiredAvailable
2018
5385380
2019
37,10723,10813,999
2020
50,38831,40518,983
2021
11,72211,7220
Total99,75566,77332,982

Risk Indicators

Additionality

VVB-confirmed combined test

Permanence

Energy project, no buffer pool stated

Leakage

0% deduction, justification contradicted

Baseline

Project-specific, method contradictory across docs

Safeguards

Confirmed in VVB report, contradicted elsewhere

Double-claim

CORSIA excluded, CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-08-26ACM0018

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents