Skip to main content
GSEnergy Efficiency - DomesticUgandaAMS-II.G

BioLite Improved Cook stoves Programme - CPA 022 supported by Republic of Korea

GS-3224 ↗ · current registry ID: GS11235

#100of 202 in Industrial#14of 23 in Uganda#253of 426 in Gold Standard (GS)#27of 46 in AMS-II.G

5.0/ 10
Integrity
5.2
Transparency
5.0
Claim Safety
5.0
Documentation
4.5

Audit Analysis

The BioLite Improved Cook Stoves Programme in Uganda is a Gold Standard energy-efficiency project with VVB-verified additionality, a measured project-specific baseline, and a quantified 5% leakage deduction. However, nine cross-document contradictions—including a 97-fold discrepancy in the fuel net replacement benefit value and a fundamental disagreement on the crediting period length (5 vs 20 years)—along with an extensive list of unresolved corrective actions and missing documentary evidence, significantly undermine confidence in the data integrity and the reliability of the claimed emission reductions.

Red Flags

  • FNRB value contradicts between the verification report (0.807) and the PDD (78.75), a discrepancy of nearly two orders of magnitude that cannot be reconciled by unit conversion alone
  • Crediting period is stated as 5 years (2019–2024) in the verification report but 20 years (2018–2038) in the validation report, fundamentally altering the pro-rata delivery calculation
  • Total ERR claimed differs between the PDD (1,498,873 tCO₂e) and the issuance document (2,649,011 tCO₂e) on the same date, with no explanation provided
  • No buffer pool percentage is stated and reversal events are explicitly not addressed, leaving permanence risk unquantified
  • Extensive corrective actions (17 items) and material findings (30+ items) indicate systemic documentation and data-quality deficiencies across the monitoring and verification cycle

Credit Vintages

IssuedRetiredAvailable
2021
7497490
2022
2,7736762,097
2023
2,87202,872
2024
2,49702,497
Total8,8911,4257,466

Risk Indicators

Additionality

VVB-confirmed combined test

Permanence

No buffer pool; reversal not addressed

Leakage

5% quantified deduction

Baseline

Project-specific, measured, reassessed 2024

Safeguards

FPIC, grievance mechanism, safeguards documented

Double-claim

CORSIA and CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-08-24AMS II G: Energy efficiency measures in thermal applications of non-renewable biomass

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents