Skip to main content
VCSEnergy industries (renewable/non-renewable sources); Waste handling and disposalChina Registry: RegisteredACM0001

Chongqing Tongliang LFG Power Generation Project

VCS-3696 ↗

#51of 204 in China#160of 629 in Verra (VCS)#10of 53 in ACM0001

6.0/ 10
Integrity
6.5
Transparency
6.0
Claim Safety
5.5
Documentation
6.0

Audit Analysis

A VCS landfill-gas power-generation project in China with a VVB-confirmed combined additionality test and no material findings, but weakened by a 0% leakage deduction that the verification report describes as 'not addressed,' a project-specific baseline with no recorded reassessment, and a verified emission-reduction figure that is roughly four times the pro-rata expectation derived from the PDD's lifetime estimate. Multiple contradictions between the 2023 and 2025 verification reports on safeguards, FPIC, and grievance mechanisms suggest the project's social-compliance documentation was substantially strengthened only recently.

Red Flags

  • Leakage deduction is 0% and the 2025 verification report records the justification as 'not addressed,' while the monitoring report calls it 'deemed negligible' — the higher-authority verification report does not support the zero deduction.
  • The verified emission reduction of 105,752 tCO₂e for the two-year monitoring period (Aug 2022 – Jul 2024) is approximately 4.2× the pro-rata expectation of ~24,989 tCO₂e derived from the PDD's 10-year lifetime estimate of 124,945 tCO₂e, raising over-crediting questions even accounting for front-loaded LFG generation.
  • Eight contradictions were identified across documents, including FPIC, grievance mechanism, benefit-sharing, and safeguards all flipping from 'not present' in the 2023 verification report to 'present' in the 2025 report, indicating the project's social-compliance record was retroactively strengthened.
  • Buffer-pool percentage, reversal-event history, FNRB method, and usage-monitoring method are all absent from the extracted record, leaving key MRV and permanence parameters unverified.

Credit Vintages

IssuedRetiredAvailable
2021
82,273082,273
2022
42,672042,672
Total124,9450124,945

Risk Indicators

Additionality

Combined test, VVB-verified, capture not legally required

Permanence

LFG power generation – no carbon storage, inherent permanenc

Leakage

0% deduction, justification 'not addressed' per verification

Baseline

Project-specific, measured per monitoring report, reassessme

Safeguards

FPIC, grievance, benefit-sharing confirmed in 2025 but absen

Double-claim

CORSIA explicitly not eligible; CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-08-24ACM0001

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents