Skip to main content
GSSmall, Low - Impact HydroIndonesiaAMS-I.D

*Salido Kecil Mini Hydropower Plant

GS-716 ↗ · current registry ID: GS423

#301of 770 in Renewable energy#6of 17 in Indonesia#194of 426 in Gold Standard (GS)#95of 417 in AMS-I.D

5.2/ 10
Integrity
5.5
Transparency
5.0
Claim Safety
5.0
Documentation
5.5

Audit Analysis

The Salido Kecil Mini Hydropower Plant is a Gold Standard grid-connected renewable project with VVB-confirmed additionality and documented safeguards, but it carries moderate integrity and claim-safety risks stemming from a project-specific baseline, a grid emission factor anchored to 2005, a 0% leakage deduction whose justification appears only in later monitoring reports, and significant year-to-year variability in verified emissions reductions (6,005 tCO₂e in 2022 vs 2,629 tCO₂e in 2024) linked to recurring operational outages.

Red Flags

  • Grid emission factor is anchored to 2005 data (0.679 tCO₂/MWh); if Indonesia's grid has decarbonised since then, the project may be over-crediting its displacement benefit.
  • Verified emissions reductions dropped from 6,005 tCO₂e (2022 monitoring report) to 2,629 tCO₂e (2024 monitoring report), a ~56% decline, driven by repeated turbine outages, controller failures, and PLN-requested shutdowns.
  • The PDD (2020) did not address leakage; the 'deemed negligible' justification appears only in the 2024 monitoring report, creating a documentation gap in the project design.
  • Material findings include an improperly located grievance book, an outdated office address in the PDD, and missing calibration evidence for monitoring equipment, yet no corrective actions were formally required.

Credit Vintages

IssuedRetiredAvailable
2007
5095090
2008
1,2221,2220
2009
1,5681,5680
2010
2,7222,7220
2011
2,6252,6250
2012
2,6522,6520
2013
3,0753,05718
2014
3,4193,4190
2015
2,9672,9670
2016
3,5883,5880
2017
6706700
2018
1,9841,832152
2019
4154087
2020
3,3762,3671,009
2021
3,7303,467263
2022
1,1131,1130
Total35,63534,1861,449

Risk Indicators

Additionality

VVB-confirmed barrier test

Permanence

Avoidance project, no buffer pool stated

Leakage

0% deduction, justification absent from PDD

Baseline

Project-specific, 2005 grid EF, no reassessment date

Safeguards

FPIC, grievance mechanism, benefit sharing documented

Double-claim

CORSIA and CCP status not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-08-24AMS I.D Grid connected renewable electricity generation

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents