Beijing Jingneng Weilai Kejicheng Gas-fired Cogeneration Project
#424of 617 in Industrial#869of 1181 in China#1030of 1514 in CDM (UNFCCC)#3of 7 in AM0107
Audit Analysis
A CDM gas-fired cogeneration EE project with an investment additionality test and a project-specific baseline reassessed in 2021, but significant evidence gaps including no grid emission factor, no FNRB value, no monitoring data, and low extraction confidence. The 0% leakage deduction is described as 'quantified' but lacks supporting detail, and the absence of any monitoring or verification reports limits confidence in the 152,530 tCO₂e claim.
Red Flags
- Grid emission factor not stated in any available document — a critical parameter for an EE supply-side project displacing grid electricity
- FNRB value and method not stated, making it impossible to assess whether the baseline reflects realistic future grid improvements
- Leakage deduction of 0% justified only as 'quantified' with no supporting calculation or explanation in the extracted record
- Low extraction confidence across the document set, with one of three source documents listed as 'unknown'
- No monitoring or verification reports found in the evidence set despite a 7-year crediting period (2020–2027)
Credit Vintages
No issuances recorded on the registry.
Risk Indicators
Investment test present; VVB confirmation not explicitly sta
EE avoidance project; no reversal risk or events reported
0% deduction labelled 'quantified' but no supporting detail
Project-specific baseline; reassessed 2021; no FNRB or grid
Safeguards mentioned and benefit sharing described; FPIC and
CORSIA and CCP statuses not stated in available documents
⚑ Dispute this rating
Are you the project owner?
Metadata correction (free)
Name, country, marketplace or links incorrect? Let us know.
Does not modify the score.
[email protected] →Pipeline re-run with new documents
Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.