Skip to main content
GSEnergy Efficiency - DomesticUgandaGeneral Methodologyv2.0

Community Carbon Efficient Cooking Programme-VPA1

GS-2926 ↗ · current registry ID: GS10967

#135of 202 in Industrial#18of 23 in Uganda#325of 426 in Gold Standard (GS)

4.7/ 10
Integrity
5.0
Transparency
4.5
Claim Safety
5.0
Documentation
4.0

Audit Analysis

A Gold Standard cookstove efficiency project in Uganda with VVB-confirmed additionality and no reversal events, but undermined by a very large volume of corrective actions and clarifications across multiple monitoring cycles, numerous cross-document contradictions (especially on leakage, ERR totals, and the fuel non-recovery baseline), and a low-confidence extraction that limits confidence in the underlying data. The project type carries inherent low permanence risk, yet the monitoring and documentation quality issues raise meaningful over-crediting concerns.

Red Flags

  • Thirteen cross-document contradictions identified, including a 24% gap in total ERR (961,642 vs 1,201,646 tCO₂e) and a leakage deduction that shifts from 0% to 5% between documents
  • 17+ open corrective actions and 40+ clarifications logged across multiple verification and validation cycles, indicating systemic monitoring and reporting quality problems
  • Fuel non-recovery baseline (FNRB) value contradicts itself: 0.89 in the 2025 verification report versus 39 in the 2025 validation report — a unit or methodology inconsistency that cannot be reconciled from the available record
  • Minimum extraction confidence rated 'low', meaning at least one key document was poorly readable, reducing reliability of all derived figures
  • Usage rate discrepancy flagged by the VVB: 94% measured in the field versus 90% used in the ER calculation, with a CAR still open to justify the difference

Credit Vintages

IssuedRetiredAvailable
2021
68,30268,28319
2022
592,292580,44711,845
2023
616,492603,89812,594
2024
587,0405,864581,176
Total1,864,1261,258,492605,634

Risk Indicators

Additionality

VVB-confirmed combined test

Permanence

Efficiency project, no reversals

Leakage

0% vs 5% contradiction across docs

Baseline

Project-specific, reassessed 2025

Safeguards

FPIC, grievance mechanism, 30 grievances resolved

Double-claim

CCP eligible, CORSIA not stated

Where to buy

+ Know where to buy this?

Listing multiple projects? Send us a CSV at [email protected].

⚑ Dispute this rating
Analysis ProvenanceScored2026-08-25General Methodology v2.0

Are you the project owner?

Metadata correction (free)

Name, country, marketplace or links incorrect? Let us know.

Does not modify the score.

[email protected]

Pipeline re-run with new documents

Have updated documentation not yet included? You can request a new run of the pipeline with the new inputs.

Submit Documents